4792Aig vz4
CERTIFICATE OF APPROVAL FOR RECORDING
1 hereby certify that the subdivision plat shown hereon has
been found to comply with'. the subdivision regulations for
the Blount County Planning Region, with the exception of such
variances, If any, as notedIn the minutes of the planning
commission, and that it he been approved by that body for
recording in the office of ta tour ty regist
CERTIFICATE OF ACCURACY
I hereby certify that the plan shown and described hereon Is
a true and correct survey to the accuracy required by the
Blount County Planning Commission and that the monuments
have been placed as shown hereon to the speclftcotions of the
Blount County Subdivision Regulations.
C'7- 10 -2S
Registered
CERTIFICATE OF OWNERSHIP AND DEDICATION
I (we) hereby certify that I' am (we are) the owner(s) of the
property shown and described hereon and that I (we) hereby
adopt this plan of subdivision with my (our) free consent,
establish the minimum building restriction lines, and dedicate
oil right-of-way, streets, alley, walks, casements, parks and
other open spaces to public or private use as noted.
%-A0-Zo7, c
Dote{
PAMELA E. BROOKS
CERTIFICATE OF THE APPROVAL OF WATER
I hereby certify that the WATER
Improvements have been Installed In an acceptable manner
and according to the specifications of the Blount County
Subdivision Regulations, except as noted hereon; or proper
provisions hove been mode for t eir installation.
Date
Signature
CERTIFICATE OF APPROVAL OF ROAD NAMES
AND PROPERTY NUMBERS (E-911)
I hereby certify that (1) the names of existing public roads
shown an this subdivision plot are correct. (2) the names of
any new roads, whether public or private, do not duplicate
any existing names and sold names are approved, and (3)
the property numbers of the lots shown on this plat are in
conformance with the E-911 System.
%11y.?S-
4.1 Date
E-911 Authorlfi
CERTIFICATE OF APPROVAL OF STREETS
This subdivision lies along an existing public road. the
improvements related to streets have been installed
according to County specifications; and according to
the specifications of the BLOUNT Planning
Commissions Subdivision Regulations, except as noted
hereon: or proper provisioryryry999 hovg been made for their
installation. � 7 / /05
Phyllis Lee Crisp, Register
Blount County Tennessee
'.. Res ff: 680162
Rec'd: 15.00 Instrument #: 3012825
State: 0.00
Clerk: 0.00 Recorded
Other: 2.00 7/17/2025 at 4:05 PM
Total: 17.00 in
Map File FILE Pgs 4792A-4792A
Approval is hereby granted for lots 1
S/D OF THE PAMELA E. BROOKS PROPERTY Blot
as being suitable for surface sewage disposal (SDD) with the listed
ELECTRICAL UTILITY SERVICE
The property shownyn is subdivision plot is within the service
area of the {-� -
The,roilowing conditlon(s) apply:
Lots I are served by existing powerlines.
O Lots are/will be served by new powerlines as per
agreement between owner of subdivision property and utility.
NOTE: In any of the above Instances, extension of the
Service connection Is the responsibility of the
Individual lot owner, In accordance with the
established policies of the utility company.
i' 1'SIZf
n Dote
/)�d Signatures i
GIN 1 3R,
Title 72
defined as
Tennessee
restrictions.
REMAINING LANDS OF
PAMELA E. BROOKS
R.B. 2106-1238
+/-29 ACRES
O
71
CLOVER MEADOWS ----------
MAP FILE 4478A
LINE TABLE
LINE
BEARING
DISTANCE
L-1
N
42.2712'
W
127.13
L-2
N
42.10 32
W
37.86
L-3
S
39-21 59
E
59.18
L-4
S
62'22 3z
W
161.04
L-5
S
56'01 39
W
59.24
L-6
S
55'0823'
W
2D.07
L-7
N
55'3419
E
81.65
L-8
N
35'02 52
W
56.61
L-9
N
35'02 52
W
47.39
L-10
N
35'02 52
W
1
70.59
L-121
S
16'40 26
W
1
30.14
Prior to any construction of a structure, mobile or,permanent, the plans for the exact house/structure
location must be approved and a SDD system permit issued by the Division of Environmental Health.
Water taps, water lines, underground utilities and driveways should be located at the side property
lines unless otherwise noted. Any cutting, filling or alterations of the soil conditions may void this
Blount County Health Department
Lots: I
are approved for standard individual sub-
surface sewage disposal system serving a
maximum of 3 bedrooms.
House design, size, location and
driveway design will determine
the actual number of bedrooms
for which a permit may be Issued.
70
69
NOTES:
1) EVERY DOCUMENT OF RECORD REVIEWED AND CONSIDERED
AS A PART OF THIS SURVEY IS NOTED HEREON. NO ABSTRACT
OF TITLE, NOR TITLE COMMITMENT, NOR RESULTS OF TITLE
SEARCHES WERE FURNISHED THE SURVEYOR. THERE MAY EXIST
OTHER DOCUMENTS OF RECORD THAT WOULD AFFECT THIS PARCEL
2) AS PER THE FLOOD INSURANCE RATE MAP (MAP NUMBER: 47009CO235C;
EFFECTIVE DATE: SEPTEMBER 19, 2007) THIS PROPERTY IS LOCATED WTHIN
ZONE X, AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE
FLOODPLAIN.
3) THIS PROPERTY IS ZONED: S (SURBURBANIZING).
4) SETBACK REQUIREMENTS: FRONT = 30 FEET, 10 FEET FROM DRIVEWAY EASEMENT
SIDE = 10 FEET
REAR = 20 FEET FOR PRINCIPAL STRUCTURE
5 FEET FOR ACCESSORY STRUCTURE
5) IRON ROD SET AT EACH CORNER, UNLESS OTHERWISE SHOWN HEREON.
6) RTK CPS. WAS USED ON 100% OF THIS SURVEY. DATUM IS NAD 83 CORS 96
(TOOT NETWORK CORRECTION). THE CPS RECEIVER WAS A CARLSON BRX7 AND
EXCEEDS DUAL FREQUENCIES. ALL CPS MEASURED POINTS WERE REDUCED TO
GROUND WITH A GRID TO GROUND FACTOR OF 1.000000. AVERAGE HRMS VALUES
RECORDED WERE LESS THAN 0.035 FEET AT EACH CORNER.
7) DRAINAGE AND UTILITIES EASEMENTS SHALL BE
FIVE FEET ON EACH SIDE OF ALL INTERIOR LOT
LINES AND TEN FEET ON THE INSIDE OF ALL LOT
LINES EXTERIOR TO THE SUBDIVISION, AND TEN
FEET ALONG THE STREET RIGHT-OF-WAY EXCEPT
AS OTHERWISE SHOWN HEREON, OR FIVE FEET ON
EACH SIDE OF ALL ASBUILT UTILITIES.
, REMAINING LANDS OF
}� PAMELA E. BROOKS
R.B. 2106-1238
+/-29 ACRES
an\
o�� \ °
Q
ADDITIONAL ROAD RIGHT—OF—WAY
DEDICATED PER MAP FILE 1598B
i
OLD CLOVER HILL ROAD—> 9'.
REMAINING LANDS OF PAMELA E. BROOKS
ACCORDING TO TENNESSEE CODE
ANNOTATED SECTION 13-3-401(4)
(B) THIS PLAT DOES NOT FALL
WITHIN THE DEFINITION OF A
"SUBDIVISION" THAT MUST E
APPROVED BY TH B T COUNTY
PLANNING COM ON.
KEVIN E. PIT LS NO. 2324
The owner and/or developer of any lot, in developing the lot Into building,
whether primary structure or accessory structure, or conducting any development
or use that will disturb soils on the lot, shall reserve and maintain area sufficient
for primary, secondary (and tertiary when appicable) septic field lines
appropriate to the size and use of buildings and other development or activities.
The Blount County Environmental Health Department should be consulted prior
to any construction to determine appropriate area to be reserved undisturbed for
septic field use.
D A DRG/�TS
;W O�
' a YER
?�FSSEE M
CERTIFICATE
\ o y sue,
.c1ld 7O.
CPP 0y�if,T°
O
°9
O
I HEREBY CERTIFY THAT I AM A SURVEYOR LICENSED TO DO SURVEYING UNDER
THE LAWS OF THE STATE OF TENNESSEE. THAT I HAVE SURVEYED THE HEREON
DESCRIBED PROPERTY. THAT THIS PLAT CORRECTLY DEPICTS THE RESULTS OF
SAID SURVEY. THAT SAME 15 TRUE AND CORRECT TO THE BEST OF MY INFOR-
MATION. KNOWLEDGE, AND BELIEF, AND THAT THE SURVEY MEETS CATAGORY IV
ACCURACY SPECIFICATIONS, THE RATIO OF PRECISION OF THE UNADJUSTED
SURVEY IS 1: 107k��
A FOOT PER CORNER
ON SMALL LOTS.
G—SITE HIDDEN
/ COVE CT.
Xg
OS'9� 5,00 �9 � Q'9
g o
141
v9
0
VICINITY MAP - NOT TO SCALE 1
F
SUBDIVISION OF THE
PAMELA E. BROOKS PROPERTY
DISTRICT 6, BLOUNT COUNTY, TENNESSEE
REF.: R.B. 2106-1238
TOTAL AREA = 1.520 Ac.
OWNERS: PAMELA E. BROOKS
3334 HWY. 411 S.
MARYWLLE, TN. 37801
GRAPHIC SCALE
1DO 0 so 100 200 400
( IN FEET )
1 inch = 100 ft. DATE: 07-
BLOUNT SURVEYS, INC.
LEGEND
TAX MAP 078
DRAWN BY:
IR(m =OLD IRON ROD (fOUNID
IND) - OLD IRON PIPE (FOUND)
1 IR(N) = NEW IRON ROD (SET)
KEVIN EDGAR PTTTS, RLS NO. C.
A1710 W. LAMAR ALEXANDER PARKWAY
MARYVILLE, TENNESSEE 37801
GROUP
GROUP
PARCEL 167.01
KP
WORt
BY' BC
AP CHECK
Y:
PHONE (865) 983-8484
M.➢.S.L. - MINIMUM BUILDING
SETBACK LINE
V=100'